Railroad Test Set (100Hz and 250Hz Cab Filters)

No reviews yet | Write A Review

AED7,813.00AED8,430.00

The Triplett 2000 Series Railroad Testers are designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment. Model 2001 includes all of the features of the Model 2000 with the addition of Cab Filters. Designed for passenger railroads using both 100Hz and 250Hz coding systems. Includes: test leads, padded water repellent carrying case, shoulder strap, and batteries.

Weight 4.05 kg
Dimensions 7 × 6.75 × 10.5 cm
Certificate

Standard, With Certificate of NIST

  • Both 100Hz and 250Hz Cab Filters
  • All Pass position bypasses Cab Filters
  • Auto Polarity in DC functions
  • Ohmmeter Voltage Mode detects foreign AC or DC Voltages
  • Relay Contact On Time (Dry Contact) requires no adjustment
  • Peak measurements require no adjustment

Product Group:  Railroad Testers

Product Type: Railroad Testers

Includes: Includes Test leads, padded water repellent carrying case, shoulder strap, and batteries.

Harmonization Code: 9030.33.3800

ECCN: EAR99

Packaging: Box

Weight lbs to kg: 4.05

Length in: 7

Width in: 6.75

Height in: 10.5

Specifications Model 2000 (Part# 2010) Model 2001 (Part# 2011) Model 2002 (Part# 2012) Model 2003 (Part# 2013)
DC Voltage 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V
DCV Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS
DC Milliamps 16mA, 60mA, 300mA 16mA, 60mA, 300mA 16mA, 60mA, 300mA 16mA, 60mA, 300mA
DC mA Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS
DC Amps 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A
DCA Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS
AC Voltage 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V
ACV Accuracy ±3.0% FS ±3.0% FS ±3.0% FS ±3.0% FS
AC Amps 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A
ACA Accuracy ±3.0% FS ±3.0% FS ±3.0% FS ±3.0% FS
Cab Filter Response
(All AC ranges)
60Hz: —
100Hz: —
200Hz: —
250Hz: —
60Hz: —
100Hz: 92 to 100Hz
200Hz: —
250Hz: 245 to 255Hz
60Hz: —
100Hz: 92 to 100Hz
200Hz: 196 to 204Hz
250Hz: —
60Hz: 57 to 63Hz
100Hz: 92 to 100Hz
200Hz: —
250Hz: —
Code Functions
(All AC and DC Ranges)
On Time: 3% to 100% (±3% FS)
Rate: 30 to 500CPM (±3% FS)
Peak Hold: Ö
Peak Follow: Ö
On Time: 3% to 100% (±3% FS)
Rate: 30 to 500CPM (±3% FS)
Peak Hold: Ö
Peak Follow: Ö
On Time: 3% to 100% (±3% FS)
Rate: 30 to 500CPM (±3% FS)
Peak Hold: Ö
Peak Follow: Ö
On Time: 3% to 100% (±3% FS)
Rate: 30 to 500CPM (±3% FS)
Peak Hold: Ö
Peak Follow: Ö
Volt Senese Mode 15V AC or DC (±20%) 15V AC or DC (±20%) 15V AC or DC (±20%) 15V AC or DC (±20%)
Resistance Range: R x 1 and R x 100
Center Scale: 5 and 500 ohms
Accuracy: ±2% of scale length
Range: R x 1 and R x 100
Center Scale: 5 and 500 ohms
Accuracy: ±2% of scale length
Range: R x 1 and R x 100
Center Scale: 5 and 500 ohms
Accuracy: ±2% of scale length
Range: R x 1 and R x 100
Center Scale: 5 and 500 ohms
Accuracy: ±2% of scale length
Dry Contact Allowable Resistance: 0 to 100 ohms
Test Voltage: 7.5 to 15VDC
Test Current: less than 1mA
Allowable Resistance: 0 to 100 ohms
Test Voltage: 7.5 to 15VDC
Test Current: less than 1mA
Allowable Resistance: 0 to 100 ohms
Test Voltage: 7.5 to 15VDC
Test Current: less than 1mA
Allowable Resistance: 0 to 100 ohms
Test Voltage: 7.5 to 15VDC
Test Current: less than 1mA
Power (2) 9V; (1) 1.5V D cell      
Dimensions 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm)
Weight 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads
Data SheetUser Manual