The Triplett 2000 Series Railroad Testers are designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment. Model 2001 includes all of the features of the Model 2000 with the addition of Cab Filters. Designed for passenger railroads using both 100Hz and 250Hz coding systems. Includes: test leads, padded water repellent carrying case, shoulder strap, and batteries.
Weight | 4.05 kg |
---|---|
Dimensions | 7 × 6.75 × 10.5 cm |
Certificate | Standard, With Certificate of NIST |
- Both 100Hz and 250Hz Cab Filters
- All Pass position bypasses Cab Filters
- Auto Polarity in DC functions
- Ohmmeter Voltage Mode detects foreign AC or DC Voltages
- Relay Contact On Time (Dry Contact) requires no adjustment
- Peak measurements require no adjustment
Product Group: Railroad Testers
Product Type: Railroad Testers
Includes: Includes Test leads, padded water repellent carrying case, shoulder strap, and batteries.
Harmonization Code: 9030.33.3800
ECCN: EAR99
Packaging: Box
Weight lbs to kg: 4.05
Length in: 7
Width in: 6.75
Height in: 10.5
Specifications | Model 2000 (Part# 2010) | Model 2001 (Part# 2011) | Model 2002 (Part# 2012) | Model 2003 (Part# 2013) |
---|---|---|---|---|
DC Voltage | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V |
DCV Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Milliamps | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA |
DC mA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
DCA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
AC Voltage | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V |
ACV Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
AC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
ACA Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
Cab Filter Response (All AC ranges) |
60Hz: — 100Hz: — 200Hz: — 250Hz: — |
60Hz: — 100Hz: 92 to 100Hz 200Hz: — 250Hz: 245 to 255Hz |
60Hz: — 100Hz: 92 to 100Hz 200Hz: 196 to 204Hz 250Hz: — |
60Hz: 57 to 63Hz 100Hz: 92 to 100Hz 200Hz: — 250Hz: — |
Code Functions (All AC and DC Ranges) |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
Volt Senese Mode | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) |
Resistance | Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Dry Contact | Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Power | (2) 9V; (1) 1.5V D cell | |||
Dimensions | 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2″ (127 x 165.1 x 81.3mm) |
Weight | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads |