MPI1103B6 (Rail/Tower Model) 3 KVA Single Phase UPS, 6 Inbuilt Batteries, 5-10 minutes Autonomy Approx at full Load (With Rail Kit, SNMP Card)

Brand BPE
No reviews yet | Write A Review

AED2,220.00

The MPI1103B6 is a reliable single-phase Uninterruptible Power Supply (UPS) designed and manufactured in India, offering robust protection against all types of power issues, making it ideal for ADP machines and other sensitive equipment. With a versatile dual-purpose design, it can be used as a tower unit or mounted on rails, providing flexibility for various installation setups. This UPS features industry-leading efficiency with a compact form factor, a comprehensive LCD display for easy monitoring and status access, and low electromagnetic interference to ensure compatibility with sensitive loads, making it a dependable solution for critical power protection needs.

  • 3 KVA Online UPS
  • Online double-conversion UPS
  • Input power factor corrected, ≥0.99
  • Output power factor 0.9
  • Wide input voltage (110Vac – 300Vac)
  • Rack- Tower 2-in -1 design
  • Hot swappable
  • ECO mode for energy saving
  • Generator compatible
  • Online double conversion efficiency up to 90 %
  • Emergency power off function (EPO)
  • Batteries: 12 V/ 9 Ah * 6
  • Model: MPI1103B6
  • Capacity: 3000 VA/ 2700 W
  • Phase: Single phase with ground

Physical

  • Standard Model
  • Dimension (DxWxH): 630 x 438 x 88 [2U]
  • Net Weight (Kgs): 29.3
  • IT Infrastructure and Networking.
  • Telecommunication Facilities
  • Healthcare and Hospitals
  • Industrial and Manufacturing Units
  • Banking and Financial Institutions
  • Commercial Buildings and Office Complexes
  • Educational Institutions
  • Renewable Energy Systems
INPUT
Nominal Voltage 200/208/220/230/240VAC
Input Voltage Range 120-300 VAC at 50% load
180-300 VAC at 100% load
Frequency Range 40Hz – 70 Hz
Power Factor ≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage 200/208/220/230/240VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 47 – 53 Hz or 57 – 63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ±0.15 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤ 3% THD (Linear Load); ≤ 5% THD (Non-linear Load)
Transfer Time AC Mode to Battery Mode : Zero
Inverter to Bypass: 4 ms (Typical)
Waveform (Batt Mode) Pure Sinewave
Efficiency (AC to AC) ≥ 90%
Battery
Battery Type & Number 12V/9 Ah x 6
Typical Charging Time 6 Hrs recovery>90% capacity
Charging Current 1.0 A
Charging Voltage 82.1 VDC ±1V
Data Sheet
Categories: BPE, UPS